Low or lack of ventilation

Low or lack of ventilation — Reduced fan speed or blocked airflow (NIBE FLM accessory)

NIBE · F1245 Ground Source Heat Pump

What does Low or lack of ventilation mean?

If a NIBE FLM accessory is installed, low or no ventilation indicates that the fan speed may be reduced, or there might be an obstruction in the ventilation system.

Common Causes

  • Air filter is blocked.
  • Exhaust air device is blocked or throttled down too much.
  • Fan speed is set to a reduced mode.
  • An external switch for changing fan speed is activated.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check and clean or replace the air filter if it is blocked.

  2. 2

    Inspect exhaust air devices to ensure they are not blocked or excessively throttled.

  3. 3

    Go to menu 1.2 and select 'normal' for the fan speed setting.

  4. 4

    Check any external switches that might be overriding the fan speed setting to a reduced mode.

  5. 5

    If the problem continues, contact your installer for ventilation system adjustment.

Browse all codes in this manual (6)
Verified technical data. Last updated: April 2026

Related Faults

Compressor does not startCompressor does not start — No heating or hot water demand, or system lockoutHigh or distracting ventilationHigh or distracting ventilation — Unadjusted ventilation or forced fan speed (NIBE FLM accessory)LP ALARM (Low Pressure Alarm)LP ALARM (Low Pressure Alarm) — Low pressure in the climate system