husqvarna FS5000

35 fault codes documented

C1D0C11

C1D0C11 - Ignition circuit short to ground (Deutz engine)

The ignition circuit has a short to ground, specific to Deutz engines. The engine cannot be started.

C1D0C15

C1D0C15 - Ignition circuit short to battery or open (Deutz engine)

The ignition circuit has a short to battery or an open circuit, specific to Deutz engines. The engine cannot be started.

C1D0D11

C1D0D11 - Hydraulic lift pump circuit short to ground

The hydraulic lift pump circuit has a short to ground. The hydraulic lift pump cannot be used for raising the blade.

C1D0D15

C1D0D15 - Hydraulic lift pump circuit short to battery or open

The hydraulic lift pump circuit has a short to battery or an open circuit. The hydraulic lift pump cannot be used for raising the blade.

C1D0E11

C1D0E11 - Hydraulic lowering valve circuit short to ground

The hydraulic lowering valve circuit has a short to ground. The hydraulic lowering valve cannot be used for lowering the blade.

C1D0E15

C1D0E15 - Hydraulic lowering valve circuit short to battery or open

The hydraulic lowering valve circuit has a short to battery or an open circuit. The hydraulic lowering valve cannot be used for lowering the blade.

C1D0111

C1D0111 - Starter circuit short to ground

The engine starter circuit has a short to ground. The engine cannot be started.

C1D0115

C1D0115 - Starter circuit short to battery or open

The engine starter circuit has a short to battery or an open circuit. The engine starter cannot be controlled, and cutting cannot continue.

C1D0211

C1D0211 - AUX2 circuit short to ground

The AUX2 circuit has a short to ground. AUX2 cannot be controlled by the HMI.

C1D0215

C1D0215 - AUX2 circuit short to battery or open

The AUX2 circuit has a short to battery or an open circuit. AUX2 cannot be controlled by the HMI.

C1D0311

C1D0311 - Blade clutch circuit short to ground

The blade clutch circuit has a short to ground. The blade clutch cannot be controlled by the HMI, and the blade might remain engaged or disengaged.

C1D0315

C1D0315 - Blade clutch circuit short to battery or open

The blade clutch circuit has a short to battery or an open circuit. The blade clutch cannot be controlled by the HMI, and the blade might remain engaged or disengaged.

C1D0611

C1D0611 - Water pump circuit short to ground

The water pump circuit has a short to ground. The water pump cannot be turned on.

C1D0615

C1D0615 - Water pump circuit short to battery or open

The water pump circuit has a short to battery or an open circuit. The water pump cannot be controlled by the HMI and may not turn on.

C1D0811

C1D0811 - AUX1 circuit short to ground

The AUX1 circuit has a short to ground. AUX1 cannot be controlled by the HMI.

C1D0815

C1D0815 - AUX1 circuit short to battery or open

The AUX1 circuit has a short to battery or an open circuit. AUX1 cannot be controlled by the HMI.

C1D0911

C1D0911 - Working light circuit short to ground

The working light circuit has a short to ground. The working light cannot be turned on.

C1D0915

C1D0915 - Working light circuit short to battery or open

The working light circuit has a short to battery or an open circuit. The working light cannot be controlled by the HMI and may not turn on.

C1E0111

C1E0111 - Blade depth sensor signal short to ground

The blade depth sensor signal has a short circuit to ground. The blade depth cannot be displayed, and the blade depth stop function cannot be used.

C1E0112

C1E0112 - Blade depth sensor signal short to battery

The blade depth sensor signal has a short circuit to the battery. The blade depth cannot be displayed, and the blade depth stop function cannot be used.

C1E0511

C1E0511 - E-track position sensor circuit short to ground

The E-track position sensor has a short circuit to ground. The machine can continue cutting, but the E-track position cannot be detected until this fault is resolved.

C1E0512

C1E0512 - E-track position sensor circuit short to battery

The E-track position sensor has a short circuit to the battery. The machine can continue cutting, but the E-track position cannot be detected until this fault is resolved.

C1F0111

C1F0111 - E-track motor A circuit short to ground

E-track motor A has a short circuit to ground. Cutting can continue, but the E-track cannot be used for drift compensation until this fault is resolved.

C1F0112

C1F0112 - E-track motor A circuit short to battery

E-track motor A has a short circuit to the battery. Cutting can continue, but the E-track cannot be used for drift compensation until this fault is resolved.

C1F0211

C1F0211 - E-track motor B circuit short to ground

E-track motor B has a short circuit to ground. Cutting can continue, but the E-track cannot be used for drift compensation until this fault is resolved.

C1F0212

C1F0212 - E-track motor B circuit short to battery

E-track motor B has a short circuit to the battery. Cutting can continue, but the E-track cannot be used for drift compensation until this fault is resolved.

C1F0513

C1F0513 - E-track motor circuit open

The E-track motor circuit is open. Cutting can continue but the E-track cannot be used for drift compensation until this fault is resolved.

C1F0521

C1F0521 - E-track motor circuit overload

The E-track motor circuit is overloaded. Cutting can continue but the E-track cannot be used for drift compensation until this fault is resolved.

C1F0522

C1F0522 - E-track motor output current openload

The E-track motor output circuit has an open load. Cutting can continue but the E-track cannot be used for drift compensation until this fault is resolved.

P060742

P060742 - IOC MPU general memory failure

The I/O Controller Microprocessor Unit (MPU) has experienced a general memory failure. The engine cannot be started, and no machine functions can be controlled.

P060745

P060745 - IOC MPU program memory failure

The I/O Controller Microprocessor Unit (MPU) has experienced a program memory failure. The engine cannot be started, and no machine functions can be controlled.

SPN codes

SPN codes (e.g., SPN 63345) - Engine related fault displayed

The machine's display shows an engine-related fault code, identified by an 'SPN' number. These codes indicate specific issues with the engine's operation and require further investigation.

U100087

U100087 - I/O Controller no CAN communication

There is no CAN communication with the I/O Controller. The engine cannot be started, and no machine functions can be controlled.

U100088

U100088 - I/O Controller software download failed

The software download for the I/O Controller has failed. The engine cannot be started, and no machine functions can be controlled.

U100187

U100187 - Engine ECU no CAN communication

There is no CAN communication with the Engine ECU. Cutting cannot continue, and no information is available from the ECU. The engine can start but RPM cannot be controlled.