husqvarna · FS5000 D / FS7000 D
The hydraulic lift pump circuit has a short to ground. The hydraulic lift pump cannot be used for raising the blade.
Click steps to track your progress.
Check the relevant relay in the relay/fuse box.
Inspect the HMI connector, the harness leading to the relay/fuse box, and the relay/fuse box connector for damage.
Repair any damage found.
Restart the system and reset the fault code.
If the problem persists, contact your service agent for further information.