C1F0513

C1F0513 - E-track motor circuit open

husqvarna · FS5000 D / FS7000 D

What does C1F0513 mean?

The E-track motor circuit is open. Cutting can continue but the E-track cannot be used for drift compensation until this fault is resolved.

Common Causes

  • Loose connection between E-track harness to Cowling harness.
  • Loose connection between E-track actuator and E-track harness.
  • Damage to E-track or its harness.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the connection between the E-track harness and the Cowling harness.

  2. 2

    Check the connection between the E-track actuator and the E-track harness.

  3. 3

    Inspect the E-track and its harness for any damage.

  4. 4

    Repair any damage found and reset the fault codes.

  5. 5

    If the problem persists, contact your service agent for further information.