Code 39-13 Fan Start Failure

Carrier · Air Conditioners & Heat Pumps

What does 39-13 mean?

The fan attempted to start but did not achieve the commanded speed. The system tried to restart the fan multiple times.

Common Causes

  • Damaged wiring or loose connections to the fan.
  • Fan blade blockage or inability to spin freely.
  • Open external fan fuse.
  • Failing fan motor.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Visually inspect all wiring and connectors for the fan, ensuring they are secure and undamaged.

  2. 2

    Check the fan blades for any physical blockages and confirm they can spin freely without resistance.

  3. 3

    Locate and check the external fan fuse; if it's blown, replace it.

  4. 4

    If no blockages or fuse issues are found, a professional technician may need to test the fan motor for resistance.