38-71

Code 38-71 VFD Compressor Lockout - Estimator — System locked out due to repeated VFD estimator faults

Carrier · Air Conditioners & Heat Pumps

What does 38-71 mean?

This lockout occurs after three continuous 'Code 38-31 VFD Compressor Fault - Estimator' events. The system will be locked out for 4 hours. This typically indicates high starting torque or potential compressor damage.

Common Causes

  • Persistent VFD estimator faults.
  • Incorrect VFD model or compressor model parameters.
  • High starting torque.
  • Compressor damage.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Wait for the 4-hour lockout period to expire.

  2. 2

    Address the underlying causes of Code 38-31 (e.g., verify correct VFD/compressor models, check for compressor damage).

  3. 3

    Contact a qualified technician for further diagnosis and repair.