E9 — Low Fuel Detection Error

Weber · SmokeFire Grills

What does E9 mean?

The grill's low fuel sensor indicates that the pellet level is critically low. The grill will automatically run a shutdown procedure if it is hot.

Common Causes

  • Dirty low fuel sensor window
  • Actual low pellet level in the hopper
  • Faulty low fuel sensor

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Allow the grill to complete its shutdown procedure and cool completely. Do not unplug or power off during shutdown.

  2. 2

    Once cooled, place a container under the hopper and pull the slide door to release pellets.

  3. 3

    Using a dry cloth or paper towel, wipe the low fuel sensor window until it is clean.

  4. 4

    Push the hopper slide door closed and refill the hopper with pellets.

  5. 5

    Power on the grill and begin a cook to allow the controller to run diagnostics. If E9 persists, contact Customer Service for low fuel sensor replacement.

Browse all codes in this manual (14)
Verified technical data. Last updated: April 2026

Related Faults

Cook CompleteCook Complete notification — Cooking has endedE1E1 — Auger JamE2E2 — Fan Error