A1

Fault A1 - Boiler communication issue

Viessmann · Vitodens 200 Boilers

What does A1 mean?

This fault indicates a general communication problem within the boiler system. It requires resetting the boiler and potentially checking internal circuit boards.

Common Causes

  • Internal communication error
  • Issue with the LGM (burner control unit) or VR20 circuit board

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Acknowledge the fault and reset the boiler.

  2. 2

    Power the boiler off and on.

  3. 3

    Remove the VR20 circuit board and reinstall it, ensuring good contact.

  4. 4

    Power the boiler off and on again.

  5. 5

    If the fault reappears, the LGM may need replacement.