EA

Fault EA (Detailed 193) — Burner fault: ionization current deviation too great

Viessmann · Vitodens 200/222 Boilers

What does EA mean?

The burner is in fault mode because the ionization current measured during calibration shows a significant deviation from its previous normal level. This indicates an unstable or inconsistent flame detection.

Common Causes

  • The ionization current lies outside the permissible range during calibration (deviation from previous level too great)

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the flue system and address any flue gas recirculation issues.

  2. 2

    If operating in open flue mode, ensure the combustion air is free from very dusty conditions.

  3. 3

    Press the reset button R on your boiler.

  4. 4

    If the fault persists after several reset attempts, the boiler coding card may need replacement, then press reset button R again.