29

Fault 29 — Open circuit at power pump module terminals 1 and L

Viessmann · Vitodens 200/222 Boilers

What does 29 mean?

An open circuit has been detected at terminals 1 and L on the Multi terminal of the power pump module. This indicates a wiring issue or a problem with safety equipment connected to these terminals.

Common Causes

  • Open circuit at terminals 1 and L on Multi terminal of the power pump module.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the physical connections at terminals 1 and L on the Multi terminal of the power pump module for any looseness or damage.

  2. 2

    Ensure any jumper or installed safety equipment connected to these terminals is correctly fitted.

  3. 3

    Press the reset button R on the boiler.

  4. 4

    If the fault persists, contact a qualified technician to inspect the wiring or pump module.