XFMR

XFMR - Transformer connected to wrong grid

SMA · Sunny Boy Series

What does XFMR mean?

The inverter's internal transformer is configured for or connected to an incorrect type of grid. This is identified as a disturbance message.

Common Causes

  • Incorrect grid connection wiring or configuration
  • Wrong settings for Delta corner grounded grids
  • Incorrect L1/L2 connections in unbalanced 208V/240V grids.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    If in Delta corner grounded grids, ensure the grid ground is correctly connected to terminal L2.

  2. 2

    In unbalanced 208V and 240V grids, try interchanging the L1 and L2 connections.

  3. 3

    Have a qualified electrician check the transformer connections and the grid type configuration of the inverter.

  4. 4

    If the issue persists, contact SMA America for assistance.