What does 4 mean?

The main control board and the IPM are not communicating. This could be due to wiring issues or a problem with one of the boards.

Common Causes

  • Faulty wiring or wiring connections
  • Damaged IPM
  • Damaged main control board

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check wiring and connections at the PCB (CN34) and IPM (CN2).

  2. 2

    Verify the correct voltage is present at the IPM CN2 connection.

  3. 3

    If connections are good and voltage is correct, replace the IPM.

  4. 4

    If communication voltage is incorrect, replace the PCB.