[18]

Error 18 — Compressor motor desynchronizing

Lennox · EL18KSLV Series Outdoor Units

What does [18] mean?

The compressor motor is out of sync. This can be caused by overload, fluctuating loads, issues with the current sensor circuit, or a missing inverter gate drive signal.

Common Causes

  • The power supply is abnormal.
  • The compressor wiring is incorrect.
  • The power module is faulty.
  • The compressor itself is faulty.
  • The system is overloaded.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the power supply voltage is normal.

  2. 2

    Ensure the wiring between the power module and compressor is correct.

  3. 3

    Check if the power module is functioning normally.

  4. 4

    Confirm the compressor is normal (check coil resistance and insulation).

  5. 5

    If the compressor load is too high, find and resolve the reason.