CodeRegistry
Brands
  1. Home
  2. Lennox
  3. EL18KSLV Series Outdoor Units
  4. 18
About·Privacy·Terms

CodeRegistry — Your global library for technical solutions.

For your safety: always follow the equipment manufacturer’s official manuals. CodeRegistry is an independent help site and is not affiliated with the brands listed here.

18

Error 18 — Compressor motor desynchronizing

Lennox · EL18KSLV Series Outdoor Units

What does 18 mean?

Loss of synchronization between the compressor windings (U, V, W) occurred during speed changes. This can be caused by unstable power, internal compressor faults, or wiring issues.

Common Causes

  • Unstable power supply
  • Internal compressor fault
  • IPM fault
  • Compressor terminal wiring incorrect
  • Poor wiring condition
  • Loose compressor wiring connection

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the stability of the power supply.

  2. 2

    Inspect compressor terminal wiring for tightness and correctness.

  3. 3

    Check the IPM for faults.

  4. 4

    If the problem persists, the compressor or IPM may need replacement.

Browse all codes in this manual (43)
Verified technical data. Last updated: April 2026

Related Faults

1Error 1 — EEPROM malfunction or damage10Error 10 — Outdoor defrost sensor failure11Error 11 — Suction temperature sensor failure
Source: Lennox EL18KSLV Series Outdoor Units
Open Manual (Page 69)Search more codes in this manual