440

Alert 440 (Flash Code 13) — Compressor Slowdown - High Heat-Sink Temperature

Lennox · Communicating Systems

What does 440 mean?

The compressor speed is slowing down due to a high heat sink temperature. The inverter LEDs will flash code 13 (Red: One Flash, Green: Three Flashes). This is often a normal operation during high outdoor temperatures.

Common Causes

  • Heat sink temperature is approaching its limit.
  • Loose screws holding the inverter to the inverter board.
  • Debris or obstructions impacting airflow across the heat sink.
  • High outdoor temperatures.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Wait five minutes for capacitors to discharge, then tighten the screws holding the heat sink to the inverter control board.

  2. 2

    Check the heat sink for debris and ensure proper airflow.

  3. 3

    Monitor heat sink temperature, compressor speed, and speed reduction status in the thermostat's diagnostics section.

  4. 4

    If the alert occurs frequently at lower temperatures, check for obstructions or debris affecting airflow.