Alert 429 (Flash Code 23) — OD Inverter DC Link Low Voltage

Lennox · Communicating Systems

What does 429 mean?

The outdoor unit's inverter has detected a low DC link voltage. If this condition occurs repeatedly, the system will lock out. The inverter LEDs will flash code 23 (Red: Two Flashes, Green: Three Flashes).

Common Causes

  • Low DC link voltage in the inverter.
  • Loose wire connections at the inverter or compressor.
  • Compressor winding resistance out of range or ground issue.
  • Input power out of range.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check wire connections (U, V, W) at the inverter plug and compressor.

  2. 2

    Check compressor winding resistance and for ground issues.

  3. 3

    Verify input power is within the acceptable range (208/230VAC +10%).

  4. 4

    Check DC Link voltage and MICOM Sensing voltage. If out of range, replace the inverter; otherwise, suspect a mechanical compressor issue.

  5. 5

    Refer to the outdoor unit service manual for detailed troubleshooting.