Red LED flashes

Red LED flashes - Indicates an alarm condition

Grundfos · ALPHA3 Pump

What does Red LED flashes mean?

The red LED on the pump's operating panel is flashing. This signals that a critical alarm has been detected, indicating a fault that prevents the pump from operating properly.

Common Causes

  • Various critical faults such as a blocked motor (code 51).
  • Serious internal fault (codes 72, 76, 85).
  • Dry running (code 57).
  • Overvoltage (code 74) or undervoltage (codes 40, 75).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Connect to the Grundfos GO Remote app via Bluetooth.

  2. 2

    Tap 'Grundfos Eye' or open the 'Alarms and warnings' menu in the app to read the specific alarm code and description.

  3. 3

    Follow the recommended remedy for the specific alarm shown in the app to address the underlying cause.

  4. 4

    Tap the 'Reset alarm' button in the app once the fault is corrected. Note that simply turning the power off and on again will not reset the alarm.