57

Dry running (57) - Water is missing or system pressure is too low

Grundfos · ALPHA3 Pump

What does 57 mean?

The pump is running without sufficient liquid or the system pressure is below the required minimum. This is a protective measure to prevent pump damage, but it halts normal operation.

Common Causes

  • Insufficient water in the heating system or circulating loop.
  • Air pockets trapped inside the pump.
  • System pressure being too low, below the pump's minimum inlet requirements.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the system's water level and ensure it is adequately filled according to system specifications.

  2. 2

    Increase the system pressure to the recommended level if it is too low.

  3. 3

    Prime and vent the pump thoroughly before attempting to restart it to remove any trapped air.

  4. 4

    Ensure all isolating valves on the pump's inlet and outlet are fully open.

Browse all codes in this manual (22)
Verified technical data. Last updated: April 2026

Related Faults

157Real-time clock out of order (157) - Internal clock malfunction40, 75Undervoltage (40, 75) - Supply voltage is too low43Turbine operation (43) - Other water sources are flowing through the stopped pump
Source: Grundfos ALPHA3 Pump
Open Manual (Page 21)Search more codes in this manual