PU

PU — Charge loop error

GE Appliances · Air Conditioning

What does PU mean?

When charging begins, the system did not reach the required busbar voltage within the set time, indicating a charge loop error. The system has shut down for protection. This is shown as 'PU' on the ODU main board LED display.

Common Causes

  • Abnormal or too low grid voltage
  • Abnormal charge loop element on the drive board
  • Damaged drive board voltage sampling circuit
  • Abnormal drive board busbar voltage sampling AD terminal

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check if the grid voltage is normal and sufficient.

  2. 2

    If grid voltage is abnormal, contact support.

  3. 3

    If grid voltage is normal, suspect a drive board issue and contact support.