What does 4 mean?

The Inverter Power Module (IPM) is not communicating with the main Printed Circuit Board (PCB). This often points to a wiring issue or a faulty board.

Common Causes

  • Wiring and connections between IPM and PCB are faulty
  • Incorrect voltage at the IPM connection

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the wiring and connections CN9 on the PCB and CN15 on the IPM.

  2. 2

    Verify correct voltage at the IPM CN15 connection.

  3. 3

    Replace the IPM if connections are good but communication fails and voltage is correct.

  4. 4

    Replace the PCB if communication voltage is incorrect.