23

Error 23 — IPM temperature too high

GE Appliances · Air Conditioning

What does 23 mean?

The Inverter Power Module (IPM) has experienced an thermal overload. This is usually due to overcharge, a plugged coil, or a sensor issue.

Common Causes

  • Overcharge of refrigerant
  • Excessively plugged outdoor coil
  • IPM temperature sensor open or shorted
  • Non-condensable in the system

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check refrigerant charge level.

  2. 2

    Clean the outdoor coil thoroughly.

  3. 3

    Inspect the IPM temperature sensor and its connections.

  4. 4

    Verify system is free of non-condensables.