Operation 5 Times / Timer 2 Times (17)

Operation LED blinks 5 times and Timer LED blinks 2 times (17) — IPM protection.

Fujitsu · 410A Multi-Zone Mini-Split Systems

What does Operation 5 Times / Timer 2 Times (17) mean?

An abnormal current value is detected at the IPM (Intelligent Power Module), possibly due to blocked heat radiation.

Common Causes

  • The outdoor fan is defective or not rotating.
  • Blocked air inlets or outlets on the outdoor unit.
  • Under-charge or over-charge in the refrigeration cycle.
  • Defective IPM or Controller PCB.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Visually inspect the outdoor unit to ensure the fan is rotating freely and is not obstructed by debris.

  2. 2

    Check that the air inlets and outlets of the outdoor unit are clear of any blockages like leaves or dirt.

  3. 3

    Clean any visible dirt or obstructions from the outdoor unit's coils and fan blades.

  4. 4

    If the error persists, professional service is required to check the fan motor or refrigeration cycle charge.