1030

Status Code 1030 - WSD Open (flashing red LED)

Fronius · Primo GEN24 Inverters

What does 1030 mean?

Status code 1030, accompanied by a flashing red operating LED, means a device in the Wired Shutdown (WSD) chain has interrupted the signal line. This could be due to a tripped surge protection device (SPD) or the bypass being removed without a trigger device installed.

Common Causes

  • WSD chain signal line interruption
  • SPD surge protection device has tripped
  • Bypass removed and no trigger device installed
  • WSD switch not in primary device position

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    If the SPD surge protection device has tripped, the inverter needs repair by an authorized specialist.

  2. 2

    Install the bypass (if it was removed) or a proper trigger device.

  3. 3

    Ensure the WSD (wired shutdown) switch is set to position 1 (WSD primary device).

  4. 4

    If the issue persists, contact Fronius-trained service personnel for diagnosis and repair.