Electrolux · Induction Range
These codes indicate a break in the temperature sensor for a specific inductor coil: 51 (Left Front), 52 (Left Rear), 54 (Right Rear), or 55 (Right Front). This can be due to a faulty sensor or its connection.
Click steps to track your progress.
Verify the element temperature sensor is correctly connected to the appropriate Induction Housing Assembly connector (refer to wiring diagram if available).
Test the inductor temperature sensor resistance (blue wires) at room temperature; it should be approximately 1000 ohms. Replace the inductor if the value is incorrect.
If the sensor and connections are good, replace the associated Generator Circuit Board for the affected zone.