Low Pressure Trip Event 32

Carrier · Heat Pumps

What does 32 mean?

The system has detected a low pressure event. It will attempt to self-mitigate. Persistent low pressure conditions will lead to a lockout (Error Code 83). The system will reset after 15 minutes.

Common Causes

  • Low Pressure Event

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    The system will attempt to self-mitigate the low pressure condition over 15 minutes.

  2. 2

    Check the refrigerant charge level in the system.

  3. 3

    Inspect the indoor airflow for any restrictions, especially in cooling mode.

  4. 4

    Check the outdoor fan operation and the outdoor coil for restrictions if the unit is in heating mode.

Browse all codes in this manual (40)
Verified technical data. Last updated: April 2026

Related Faults

1 (1 sec ON), longer pause (2 sec OFF)Amber LED flashes 1 time (1 sec ON) then longer pause (2 sec OFF) — Variable Capacity Range Cutback1, pauseAmber LED flashes 1 time then pauses — Variable Capacity Operation16Communication Loss Event 16
Source: Carrier Heat Pumps
Open Manual (Page 20)Search more codes in this manual