CodeRegistry
Brands
  1. Home
  2. Bosch
  3. Compress 7000 Heat Pumps
  4. 5438
About·Privacy·Terms

CodeRegistry — Your global library for technical solutions.

For your safety: always follow the equipment manufacturer’s official manuals. CodeRegistry is an independent help site and is not affiliated with the brands listed here.

5438

Warning Z1 High pressure sensor JR1 open circuit — High pressure sensor voltage below 0.5 V DC

Bosch · Compress 7000 Heat Pumps

What does 5438 mean?

This warning indicates that the voltage on terminal 16 on the I/O module is below 0.5 V DC. This typically suggests a poor connection, a defective pressure sensor JR1, or a faulty I/O module.

Common Causes

  • Poor connection in cabling or terminal 16,18 on the I/O module.
  • Defective pressure sensor JR1.
  • Defective I/O module.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the cabling and terminal connections (16 and 18) on the I/O module, ensuring they are secure.

  2. 2

    If the warning persists, contact a qualified technician to measure voltage between terminals 18 and 16 with the sensor disconnected.

  3. 3

    Do not attempt to replace sensors or I/O modules yourself unless you are a qualified installer.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

1001/A2xNo communication betw. system controller and remote control — Room sensor error A21-A241010No communication via EMS BUS connection — Device not receiving EMS token1051No communication with external room temp. sensor module — Incorrect software setting for heating circuit 1
Source: Bosch Compress 7000 Heat Pumps
Open Manual (Page 24)Search more codes in this manual