CodeRegistry
Brands
  1. Home
  2. Bosch
  3. Compress 7000 Heat Pumps
  4. 5395
About·Privacy·Terms

CodeRegistry — Your global library for technical solutions.

For your safety: always follow the equipment manufacturer’s official manuals. CodeRegistry is an independent help site and is not affiliated with the brands listed here.

5395

Alarm Z1 Internal compressor driver fault 1 — Repeated compressor driver warning

Bosch · Compress 7000 Heat Pumps

What does 5395 mean?

This alarm indicates a persistent issue with the compressor's internal driver, triggered if three warnings (code 5394) are registered within three hours, or if the warning is continuously active for 30 minutes.

Common Causes

  • Incorrect setting on the rotary encoder/selector P on the Heat Pump's I/O module.
  • Electrical fault within the compressor.
  • Defective inverter.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the P-selector setting on the Heat Pump's I/O module. P=4 for 13 kW 3N~ and P=6 for 13 kW 1N~.

  2. 2

    If the setting is correct, contact a qualified technician to inspect the compressor for electrical faults.

  3. 3

    Do not attempt to replace major components like the inverter or compressor yourself.