CodeRegistry
Brands
  1. Home
  2. Bosch
  3. Compress 7000 Heat Pumps
  4. 5351
About·Privacy·Terms

CodeRegistry — Your global library for technical solutions.

For your safety: always follow the equipment manufacturer’s official manuals. CodeRegistry is an independent help site and is not affiliated with the brands listed here.

5351

Alarm Z1 Driving failure on compressor — Repeated compressor driving failure

Bosch · Compress 7000 Heat Pumps

What does 5351 mean?

This alarm triggers if three warnings (code 5350) are registered within three hours, or if the warning is active for 30 minutes. It indicates a persistent problem with the compressor motor failing to start or synchronize.

Common Causes

  • Bad cabling connection between the inverter and compressor.
  • Oil or liquid present in the compressor during a start attempt.
  • Bad temperature reading from compressor sensor TR1.
  • Improper setting of rotary encoders (A- and P-selectors) on the I/O module.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the cabling and connections between the inverter and the compressor for any loose wires.

  2. 2

    Verify that the A- and P-selectors (rotary encoders) on the I/O module are set correctly according to your wiring diagram.

  3. 3

    If the alarm persists, contact a qualified technician for further diagnosis and repair.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

1001/A2xNo communication betw. system controller and remote control — Room sensor error A21-A241010No communication via EMS BUS connection — Device not receiving EMS token1051No communication with external room temp. sensor module — Incorrect software setting for heating circuit 1
Source: Bosch Compress 7000 Heat Pumps
Open Manual (Page 19)Search more codes in this manual