5347

Warning Z1 Undervoltage at power supply — Incoming AC voltage too low

Bosch · Compress 7000 Heat Pumps

What does 5347 mean?

This warning indicates that the incoming AC voltage to the inverter has dropped below 165 V for 10 seconds, or below 180 V for 0.5 seconds. The warning resets automatically after 2 minutes if voltage returns above 190 V.

Common Causes

  • Bad connection in mains voltage to either the indoor or outdoor unit.
  • Low incoming mains voltage to the unit.
  • Low incoming mains voltage to the installer module.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the main supply voltage connections to both the indoor and outdoor units for secure fit.

  2. 2

    If undervoltage warnings are repeated frequently, contact your electricity supplier to report low incoming mains voltage.

  3. 3

    Ensure all electrical connections are clean and free from corrosion.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026