130

130 — Fumes NTC tripped due to overtemperature

Baxi · Duotec+ GA Compact Boilers

What does 130 mean?

The fumes NTC sensor has detected an excessively high temperature in the flue system, causing a safety trip. This protects against dangerous conditions.

Common Causes

  • Insufficient circulation of water in the system
  • Presence of scale or blockages in the heat exchanger
  • Faulty fumes NTC probe

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Press and hold down the Reset button for 2 seconds to try clearing the fault.

  2. 2

    Ensure all radiator valves are fully open to allow proper water circulation throughout the heating system.

  3. 3

    Check the boiler pressure and top up if it's too low (refer to 'FILLING THE SYSTEM').

  4. 4

    If the fault persists, contact an Authorised Service Centre to check the heat exchanger and fumes NTC probe.

Browse all codes in this manual (37)
Verified technical data. Last updated: April 2026