109

109 — Air in boiler circuit (temporary fault)

Baxi · Duotec+ GA Compact Boilers

What does 109 mean?

There is air trapped within the boiler's heating circuit, which can interfere with water circulation and heating efficiency. This is often a temporary issue.

Common Causes

  • Air bubbles in the system after filling or maintenance
  • Pump not operating correctly
  • Issues with pump power input wiring

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Press and hold down the Reset button for 2 seconds to try clearing the fault.

  2. 2

    Check the system pressure and top up if necessary as per the 'FILLING THE SYSTEM' section.

  3. 3

    Bleed any radiators in the system to remove trapped air. Start with the lowest radiator and work your way up.

  4. 4

    If the fault persists, contact an Authorised Service Centre to check pump operation.