Fault 59 - 202

Fault 59 - 202 — Mass flow rate in solar system too low

Worcester Bosch · Greenstar CDi Boilers

What does Fault 59 - 202 mean?

The display shows 'Fault 59' with a sub-code '202', indicating that the mass flow rate in the solar system for collector group 1 is too low.

Common Causes

  • Incorrect setting of mass flow in the solar system.
  • Flow restrictor on the solar station is too closed.
  • Incorrect settings for collector area, type, or climate zone in the Solar optimisation menu.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Adjust the mass flow in the solar system, for example, by increasing the pump speed.

  2. 2

    If applicable, open the flow restrictor on the solar station more.

  3. 3

    Check and correct the settings for collector area, type, and climate zone in the Solar optimisation menu.