Wilo Yonos PICO Pumps

17 fault codes documented

Bars bottom to top blink

Bars bottom to top blink - Pump venting function active

The LED display shows bars running from bottom to top. This indicates that the pump venting function is active.

Building does not get warm

Building does not get warm - Heating output too low

The building is not getting warm, suggesting the thermal output of the heating surfaces is too low for the pump's current setting.

E04

E04 - Undervoltage detected

The LED display shows E04, indicating that the power supply voltage to the pump is too low. The pump may switch off.

E05

E05 - Overvoltage detected

The LED display shows E05, indicating that the power supply voltage to the pump is too high. The pump may switch off.

E07

E07 - Generator operation (no mains voltage)

The LED display shows E07, indicating that water is flowing through the pump but it has no mains voltage. This is sometimes referred to as generator operation.

E10

E10 - Rotor blocked

The LED display shows E10, indicating that the pump's rotor is blocked. The pump may switch off and attempt to restart.

E11

E11 - Dry run detected

The LED display shows E11, indicating a dry run situation, meaning there is air in the pump. The pump may switch off or run with limited output.

E21

E21 - Overload

The LED display shows E21, indicating an overload condition. This could be due to a sluggish motor or the pump operating outside its specifications, possibly with high module temperature. The pump speed will be lower than normal.

E23

E23 - Short-circuit

The LED display shows E23, indicating a short-circuit or that the motor current is too high. The pump will likely switch off.

E25

E25 - Winding defective

The LED display shows E25, indicating a defect in the motor winding. The pump will likely switch off.

E30

E30 - Module overheating

The LED display shows E30, indicating that the interior of the control module has become too warm. The pump may switch off.

E36

E36 - Module defective

The LED display shows E36, indicating that the electronics within the control module are defective. The pump will likely switch off.

Green LED flash

Green LED flash - Restart or Venting function activated

The function LED briefly flashes green when the manual restart or the pump venting function is activated.

Outer segments clockwise blink

Outer segments clockwise blink - Restarting or Venting active

The LED display shows the outer segments in a clockwise fashion. This indicates that a restart or the pump venting function is active.

Pump making noises

Pump making noises - Potential cavitation

The pump is making unusual noises, which could indicate cavitation. This happens when there isn't enough pressure in the suction line.

Pump not running

Pump not running when power is on

The pump is not operating even though the power supply is switched on. This could be due to a fuse issue or a power interruption.

Red LED solid

Red LED solid - Fault signal active

The fault signal LED lights up solid red, indicating an active fault condition. The pump may switch off and attempt to restart depending on the error code.