EA

EA — Ionization current outside permissible range during calibration (deviation too great)

Viessmann · Vitodens 200-W B2HB Boiler

What does EA mean?

The burner is in a fault mode because the ionization current during calibration deviates too greatly from its previous level, indicating an inconsistency.

Common Causes

  • Flue gas recirculation in the flue system
  • Very dusty conditions for combustion air in open flue mode
  • Faulty boiler coding card

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Press the reset button 'R' on the boiler.

  2. 2

    If in open flue mode, ensure the combustion air intake area is clean and free of excessive dust.

  3. 3

    Contact a qualified heating technician to check the flue system for recirculation or, if several reset attempts fail, to replace the boiler coding card.

Browse all codes in this manual (56)
Verified technical data. Last updated: April 2026