CodeRegistry
Brands
  1. Home
  2. Viessmann
  3. Vitodens 200-W B2HB Boiler
  4. DF
About·Privacy·Terms

CodeRegistry — Your global library for technical solutions.

For your safety: always follow the equipment manufacturer’s official manuals. CodeRegistry is an independent help site and is not affiliated with the brands listed here.

DF

DF — Room temperature sensor cable broken (heating circuit 3 with mixing valve)

Viessmann · Vitodens 200-W B2HB Boiler

What does DF mean?

The boiler is operating without room temperature influence for heating circuit 3 (with a mixing valve) because its room temperature sensor cable is broken.

Common Causes

  • Broken cable connected to the room temperature sensor for heating circuit 3
  • Loose connection at the room temperature sensor or remote control

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Visually inspect the connecting cable of the room temperature sensor for heating circuit 3 for any breaks, cuts, or loose connections.

  2. 2

    Check the settings of the remote control for heating circuit 3 (see page 83 of the manual).

  3. 3

    If the cable is damaged or the fault persists, contact a qualified heating technician to repair or replace the cable or sensor.

Browse all codes in this manual (56)
Verified technical data. Last updated: April 2026

Related Faults

0F0F — Boiler requires service1010 — Short circuit on outdoor temperature sensor1818 — Outdoor temperature sensor cable broken
Source: Viessmann Vitodens 200-W B2HB Boiler
Open Manual (Page 79)Search more codes in this manual