F.381

F.381 — Burner in fault state: Flame loss during operation phase

Viessmann · Vitodens 100-W Boiler

What does F.381 mean?

The burner is in a fault state due to a flame loss during its normal operating phase. This indicates a sustained issue with flame stability.

Common Causes

  • Insufficient gas supply or low gas pressure
  • Flue gas recirculation in balanced flue system
  • Incorrect clearance or contamination of ionization electrode and/or flame body assembly

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check your gas supply and ensure the gas pressure is sufficient.

  2. 2

    Inspect the balanced flue system for any signs of flue gas recirculation.

  3. 3

    Check the ionization electrode and flame body assembly for correct clearance and contamination. Reset the boiler afterwards.