Vaillant · ecoTEC plus Boilers
The boiler is faulting and showing F80 and F91, indicating a problem with the actoSTOR (shift load pump) inlet sensor or its associated wiring. This is often linked to the cylinder not charging.
Click steps to track your progress.
Inspect the NTC sensor and its cable for any damage or defects.
Check the plug connections on the NTC and the actoSTOR electronics for a secure fit.
Look for any signs of a short circuit in the cable harness or where the sensor plug meets the casing.
If issues persist, the NTC sensor itself may be defective and require replacement (contact a technician).