F35

F35 Fault — Air/flue gas duct restriction or blockage

Vaillant · ecoTEC plus Boilers

What does F35 mean?

A fault has been detected in the air/flue gas duct, indicating a restriction or blockage that prevents proper air supply for combustion or discharge of flue gas.

Common Causes

  • Restriction or blockage in the air/flue pipe caused by obstructions or damage
  • Air/flue pipe not installed in accordance with recognised rules
  • Flue run restrictions
  • Flue seals issue
  • Airways of heat exchanger unclean

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the entire air/flue pipe for any obstructions, damage, or improper design.

  2. 2

    Ensure the air/flue pipe is installed according to recognized rules.

  3. 3

    Clear any detected faults in the product and restart it.

  4. 4

    Check the flue run for restrictions and inspect flue seals.

  5. 5

    Check the airways of the heat exchanger and clean the burner if necessary (requires specialist tools).