121

Isolation Fault PV — PV Isolation fault

SolarEdge · Inverters

What does 121 mean?

The inverter has detected that the solar panel array is not properly isolated from the ground. This is a serious safety issue due to potential electrical shock hazards.

Common Causes

  • Poor insulation in the PV wiring
  • Ground leakage in the solar array
  • Faulty components in the PV installation

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the PV installation for any isolation problems or ground leakage.

  2. 2

    A certified PV installer must fix any faulty strings before connecting them to the inverter.

  3. 3

    Refer to the application note on isolation fault troubleshooting for more details.