Siemens · SINAMICS V70 Drives
The tool change process fails, leading to the tool not changing, an incorrect tool being selected, or the turret continuously rotating.
Click steps to track your progress.
Check whether the phase sequence of the connection of the machine power supply and/or turret motor is correct.
Check the interface of turret rotation signal output/turret in-position signal input on the back of the PPU for damage, loose wires, or incorrect connections (e.g., terminals 1 and 10).
Check whether the wires between the turret signal input/output interface on the back of the PPU and the turret are loose or damaged.
Check whether the turret signal encoder on the machine is damaged.
If the fault still exists after these inspections, professional replacement and maintenance are necessary as the PPU is likely damaged.