Siemens · SINAMICS V70 Drives
The spindle does not move, and the PPU screen displays a message indicating it is waiting for a spindle signal, without issuing any specific alarm.
Click steps to track your progress.
Check the setting of machine data MD30200 (1 for spindle with encoder, 0 for without).
If using an analog spindle, check interface X54 on the back of the PPU for looseness or damage, and measure voltage output on pins 1 and 9 after starting the spindle.
Check whether the connection cables of the PPU, spindle drive, and encoder are in good condition.
Verify the settings of machine data MD30130, MD30240 (encoder type), MD30134 (spindle output polarity), and MD32250/MD32260 (rated motor speed consistency).
Check whether the spindle drive has a fault.
If the fault still exists after these inspections, professional replacement and maintenance are necessary as the PPU is likely damaged.