Axis not moving

Feed axis fault: Screen shows movement values, but axis does not move

Siemens · SINAMICS V70 Drives

What does Axis not moving mean?

The PPU screen indicates that the feed axis is moving, but the physical axis remains stationary. This suggests a disconnection between the control system and the mechanical movement.

Common Causes

  • Control system is in the program test state (status LED lit, PRT icon active)
  • Mechanical coupling is loose
  • Connections between the control system and the drives are not in good condition
  • Damaged drive terminals or damaged PPU

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check whether the control system is in the program test state (status LED for program test on MCP must be off, PRT icon on PPU screen must be deactivated).

  2. 2

    Check whether the mechanical coupling is loose and secure it if necessary.

  3. 3

    Verify that the connections between the control system and the drives are in good condition and that the terminals on the drives are not damaged.

  4. 4

    If the fault still exists after these inspections, professional replacement and maintenance are necessary as the PPU is likely damaged.