416

Error 416 — Compressor operation stop due to discharge temperature protection control

Samsung · Intesis Home Automation

What does 416 mean?

The compressor has shut down because the discharge temperature of the refrigerant was excessively high, triggering a safety mechanism. This protects the compressor from overheating damage.

Common Causes

  • Refrigerant overcharge or non-condensable gases in the system
  • Dirty condenser coil restricting heat rejection
  • Faulty outdoor fan causing inadequate airflow
  • Restriction in the liquid line or suction line

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Switch off the outdoor unit's power and let it cool down for at least 30-60 minutes.

  2. 2

    Clean the outdoor coil thoroughly to ensure proper heat rejection and airflow.

  3. 3

    Check that the outdoor fan is operating correctly and not obstructed.

  4. 4

    Ensure no objects are blocking airflow around the outdoor unit.

  5. 5

    This issue typically requires a professional technician to diagnose and resolve, as it may involve refrigerant levels or compressor health.