Fault code 16 — Overload protection in cooling mode

Rheem · Air Handlers

What does 16 mean?

The unit is in overload protection during cooling mode. This can be caused by too much refrigerant, high outdoor temperatures, blocked airflow, a dirty condenser, or a faulty fan or expansion valve.

Common Causes

  • The refrigerant is excessive
  • The outdoor ambient temperature is too high
  • Short-circuit occurs in the air outlet and air inlet of the outdoor unit
  • The condenser coil is dirty
  • The speed of the outdoor fan motor is too low
  • The outdoor fan is broken or the outdoor fan is blocked
  • The air inlet and outlet have been blocked
  • The expansion valve fails

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Clean the condenser coil.

  2. 2

    Remove any obstacles blocking the air inlet or outlet.

  3. 3

    Check the outdoor fan motor and its capacitor.

  4. 4

    If the problem persists, consider checking the refrigerant levels and the expansion valve.