Panasonic Air Conditioning
53 fault codes documented
Error code on Timer display LCD - Specific fault identified
An error code is displayed on the control panel's timer display LCD, indicating a specific fault or abnormality within the system. The OFF/ON LED will also blink.
F12 - Pressure switch activate
The pressure switch has activated multiple times within a short period, indicating a potential issue with system pressure regulation. The system stops if this occurs 4 times in 20 minutes.
F14 - Outdoor compressor abnormal revolution
The outdoor compressor is rotating abnormally. This fault is triggered if it occurs 4 times within 20 minutes.
F15 — Outdoor fan motor lock abnormality
This error means the outdoor fan motor is locked or malfunctioning. It is reported after 2 occurrences within 30 minutes.
F16 error - Excessive running current (UD models)
The outdoor unit's running current has exceeded a safe limit. The system will stop operation after multiple occurrences.
F20 error - Compressor overheating (UD models)
The compressor's internal temperature has exceeded the safety limit. The compressor will stop to prevent damage.
F22 — IPM (power transistor) overheating protection
This indicates the power transistor (IPM) is overheating. This protection activates after 3 occurrences within 30 minutes.
F23 error - DC peak current exceeded (UD models)
The current to the IPM module has exceeded the set value multiple times. The system will stop operation.
F24 — Refrigeration cycle abnormality
This error indicates an issue within the refrigeration cycle. It occurs if the abnormality is detected 2 times within 20 minutes.
F25 — Cooling/Heating cycle changeover abnormality
This code appears when there's an abnormality in switching between cooling and heating cycles. It is reported after 4 occurrences within 30 minutes.
F27 - Pressure switch abnormality
The pressure switch is indicating an abnormality. Protection control activates after the condition is sustained for 1 minute.
F29 — Low Discharge Superheat
This error is logged if low discharge superheat is detected once within 2550 minutes.
F30 — Water outlet sensor 2 abnormality
This error signifies an abnormality with the water outlet sensor 2. It triggers if the condition persists for 5 seconds.
F36 — Outdoor air temperature sensor abnormality
This code indicates an issue with the outdoor air temperature sensor. It is displayed if the abnormality persists for 5 seconds.
F37 — Indoor water inlet temperature sensor abnormality
This error relates to an abnormality with the indoor water inlet temperature sensor. It is shown if the issue continues for 5 seconds.
F40 — Outdoor discharge pipe temperature sensor abnormality
This error indicates an abnormality with the outdoor discharge pipe temperature sensor, lasting for 5 seconds.
F41 - PFC control abnormality
The Power Factor Correction (PFC) control system is experiencing an abnormality. This fault occurs 4 times within 10 minutes.
F42 — Outdoor heat exchanger temperature sensor abnormality
This error signifies an abnormality with the outdoor heat exchanger temperature sensor. It appears if the issue persists for 5 seconds.
F43 — Outdoor defrost sensor abnormality
This code indicates an abnormality with the outdoor defrost sensor. It is displayed if the condition persists for 5 seconds.
F45 — Indoor water outlet temperature sensor abnormality
This error relates to an abnormality with the indoor water outlet temperature sensor. It triggers if the issue continues for 5 seconds.
F46 — Outdoor Current Transformer open circuit
This error indicates an open circuit in the Outdoor Current Transformer.
F48 — Outdoor EVA outlet temperature sensor abnormality
This error indicates an abnormality with the outdoor EVA outlet temperature sensor. It appears if the issue persists for 5 seconds.
F49 — Outdoor bypass outlet temperature sensor abnormality
This code indicates an abnormality with the outdoor bypass outlet temperature sensor. It is displayed if the condition persists for 5 seconds.
F95 — Cooling high pressure overload protection
This error signifies an overload protection in the cooling high-pressure system.
Flow Switch Low — No water flow detected
The unit has detected that there is no water flow. The flow switch acts as an overload protector and will shut down the unit if the water level is too low.
H00 - No abnormality detected
This code indicates that the system is operating normally and no errors or protection controls have been activated. It's a status indicator, not a fault.
H12 — Indoor/Outdoor capacity unmatched
This error means the capacity of the indoor and outdoor units do not match. It appears about 90 seconds after power supply is turned on.
H15 — Outdoor compressor temperature sensor abnormality
This indicates an abnormality with the outdoor compressor temperature sensor. It is reported if the issue persists for 5 seconds.
H20 — Water pump abnormality
This code signifies a malfunction with the water pump. The error is indicated if the abnormality persists for 10 seconds.
H23 — Indoor refrigerant liquid temperature sensor abnormality
This error relates to an abnormality with the indoor refrigerant liquid temperature sensor. It is shown if the condition persists for 5 seconds.
H27 — Service valve error
This error indicates a problem with the service valve. It is logged if the issue persists for 5 minutes.
H28 — Abnormal solar sensor
This code indicates an abnormality with the solar sensor. It is displayed if the condition persists for 5 seconds.
H31 — Abnormal swimming pool sensor
This error relates to an abnormality with the swimming pool sensor. It triggers if the issue continues for 5 seconds.
H36 — Abnormal buffer tank sensor
This code indicates an abnormality with the buffer tank sensor. It is displayed if the condition persists for 5 seconds.
H42 — Compressor low pressure abnormality
This indicates an abnormality in compressor low pressure.
H43 — Abnormal Zone 1 sensor
This error signifies an abnormality with the Zone 1 sensor. It is displayed if the condition persists for 5 seconds.
H44 — Abnormal Zone 2 sensor
This code indicates an abnormality with the Zone 2 sensor. It is displayed if the condition persists for 5 seconds.
H62 error - Abnormal water flow detected
The system has detected a low water flow for a continuous period. The water pump and compressor will shut off permanently.
H63 — Refrigerant low pressure abnormality
This code indicates a low pressure abnormality in the refrigerant. It triggers if the condition persists for 5 seconds.
H64 — Refrigerant high pressure abnormality
This error signifies a high pressure abnormality in the refrigerant. It is reported if the condition persists for 5 seconds.
H65 — Deice circulation error
This error indicates a problem during the de-icing circulation process. It is logged if the issue persists for 10 seconds.
H67 — Abnormal External Thermistor 1
This code indicates an abnormality with the external thermistor 1. It is displayed if the condition persists for 5 seconds.
H68 — Abnormal External Thermistor 2
This code indicates an abnormality with the external thermistor 2. It is displayed if the condition persists for 5 seconds.
H70 - Back-up heater OLP abnormality
The overload protector (OLP) for the back-up heater has activated or is disconnected. Protection control activates after 60 seconds of detection.
H72 — Tank sensor abnormal
This code indicates an abnormality with the tank sensor. It is displayed if the condition persists for 5 seconds.
H76 — Indoor - control panel communication abnormality
This error indicates a communication problem between the indoor unit and the control panel.
H90 — Indoor/outdoor abnormal communication
This error means there is abnormal communication between the indoor and outdoor units. It is detected over 1 minute after operation starts.
H91 - Tank heater OLP abnormality
The overload protector (OLP) for the tank heater has tripped or is disconnected. Protection control is activated after 60 seconds of detection.
H95 - Indoor/Outdoor wrong connection
The indoor and outdoor units are connected incorrectly. This requires verification of the supply voltage connection.
H98 — Outdoor high pressure overload protection
This error signifies an overload protection in the outdoor high-pressure system.
H99 — Indoor heat exchanger freeze prevention
This code indicates that the indoor heat exchanger freeze prevention system has activated.
OFF/ON LED blinking - System abnormality or protection activated
The OFF/ON control panel LED is blinking, signaling that the system has stopped due to an abnormality or protection control activation. An error code should be visible on the timer display.
Operation LED blinking - Abnormal operation detected
The Operation LED is blinking, indicating that the system has detected an abnormality during operation. This signals a fault that requires diagnosis.