Unsuccessful defrosting 236

Alarm 236 (or 228, 2) Unsuccessful defrosting — System temperature or flow is too low

NIBE · S2125 Air/Water Heat Pump

What does Unsuccessful defrosting 236 mean?

This alarm appears after 10 consecutive failed defrosting attempts, typically due to low system temperature, poor flow, or insufficient available system volume.

Common Causes

  • System temperature or flow is too low.
  • Insufficient available system volume.
  • Significant wind effect on the outdoor unit.
  • Poor heat transfer in the system.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the indoor module/control module for further instructions or specific defrosting settings.

  2. 2

    Ensure the air flow to S2125 is not blocked by foreign objects, which can affect defrosting efficiency.

  3. 3

    Inspect the outdoor unit for significant ice buildup on the fan, grille, and/or fan cone.

  4. 4

    If the problem recurs, activate 'fan de-icing' or 'continuous fan de-icing' in the indoor module/control module settings.

Browse all codes in this manual (55)
Verified technical data. Last updated: April 2026

Related Faults

Communication fault to Inverter 254Alarm 254 (or 264, 203) Communication fault to Inverter — Inverter unpowered or brokenCompressor speed too low 354Alarm 354 (or 503, 186) Compressor speed too low — Inverter safety function reduces compressor speedContinuous light CPULED: CPU Continuous light — CPU is not running correctly