Phase failure 333

Alarm 333 (or 447, 130) Phase failure — Compressor phase is missing

NIBE · S2125 Air/Water Heat Pump

What does Phase failure 333 mean?

This alarm indicates that a compressor phase is missing, occurring 3 times within 2 hours or continuously for 1 minute, often due to a disruption in supply voltage or incorrect wiring.

Common Causes

  • Disruption in supply voltage.
  • Compressor phase is missing.
  • Incorrectly connected compressor cable.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the indoor module/control module display for specific action instructions.

  2. 2

    Verify all supply cables to the Heat Pump are connected and secure.

  3. 3

    Check the group and main fuses of the accommodation and the Heat Pump’s fuses.

  4. 4

    If the alarm persists, contact a qualified electrician to check the phase supply and compressor wiring.

Browse all codes in this manual (55)
Verified technical data. Last updated: April 2026

Related Faults

Communication fault to Inverter 254Alarm 254 (or 264, 203) Communication fault to Inverter — Inverter unpowered or brokenCompressor speed too low 354Alarm 354 (or 503, 186) Compressor speed too low — Inverter safety function reduces compressor speedContinuous light CPULED: CPU Continuous light — CPU is not running correctly