Not lit INT COM (green)

LED: INT COM (green) Not lit — No communication with inverter

NIBE · S2125 Air/Water Heat Pump

What does Not lit INT COM (green) mean?

The green INT COM LED on the base board (AA2) is not lit, indicating a lack of communication with the inverter.

Common Causes

  • Poor connection between the PCB and the inverter.
  • Inverter is unpowered or defective.
  • Communication fault on the base board or inverter.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the indoor module/control module display for communication fault alarms (e.g., Alarm 254).

  2. 2

    Verify all supply cables to the Heat Pump are connected, ensuring the inverter has power.

  3. 3

    Try resetting the Heat Pump by briefly disconnecting and reconnecting its main power supply (via circuit breaker).

  4. 4

    If the LED remains off, contact a qualified technician to inspect the inverter and its connections.

Browse all codes in this manual (55)
Verified technical data. Last updated: April 2026

Related Faults

Communication fault to Inverter 254Alarm 254 (or 264, 203) Communication fault to Inverter — Inverter unpowered or brokenCompressor speed too low 354Alarm 354 (or 503, 186) Compressor speed too low — Inverter safety function reduces compressor speedContinuous light CPULED: CPU Continuous light — CPU is not running correctly
Source: NIBE S2125 Air/Water Heat Pump
Open Manual (Page 32)Search more codes in this manual