Exchange Sensors flow / return 234

Alarm 234 (or 225, 8) Exchange sensors flow / return — Supply and return lines are switched

NIBE · S2125 Air/Water Heat Pump

What does Exchange Sensors flow / return 234 mean?

This alarm means the return line is hotter than the flow line, indicating that the supply and return lines, or their sensors, have been incorrectly connected.

Common Causes

  • Supply and return lines have been switched.
  • Flow and return sensors are incorrectly connected.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the indoor module/control module display for specific action instructions.

  2. 2

    Verify the physical connections of the supply and return lines to ensure they are not reversed.

  3. 3

    If comfortable and safe, visually inspect the flow and return sensors to confirm they are attached to the correct pipes.

  4. 4

    Contact a qualified technician to verify plumbing and sensor connections.

Browse all codes in this manual (55)
Verified technical data. Last updated: April 2026

Related Faults

Communication fault to Inverter 254Alarm 254 (or 264, 203) Communication fault to Inverter — Inverter unpowered or brokenCompressor speed too low 354Alarm 354 (or 503, 186) Compressor speed too low — Inverter safety function reduces compressor speedContinuous light CPULED: CPU Continuous light — CPU is not running correctly
Source: NIBE S2125 Air/Water Heat Pump
Open Manual (Page 42)Search more codes in this manual