Sens flt:BT71 128

Sens flt:BT71 128 — Heating medium return (external) sensor fault

Nibe · Ground Source Heat Pumps

What does Sens flt:BT71 128 mean?

This B alarm indicates a continuous fault with the heating medium return (external) sensor (BT71). This could be due to open/short circuits or a defective sensor. Heating may be blocked in conjunction with alarm 25.

Common Causes

  • Open-circuit or short-circuit on sensor input
  • Defective heating medium return (external) sensor
  • Continuous contact issue with the sensor

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the connections for the external heating medium return sensor.

  2. 2

    Check the sensor for any damage.

  3. 3

    This alarm typically resets automatically once the fault is rectified.

  4. 4

    If the service technician symbol remains, contact your installer.